seller: ПРОФПРИБОР
Kazakhstan, Akmola reg., Astana, Kubrina st., 26

Phone:

show phone
Fluke 414D/62 MAX + Laser Distance Meter/Infrared Thermometer Combo Kit

Fluke 414D/62 MAX + Laser Distance Meter/Infrared Thermometer Combo Kit

Fluke 414D/62 MAX + Laser Distance Meter/Infrared Thermometer Combo Kit
check the price
retail & wholesale
in stock
☎ show phone
FL62MAX+/323/1AC ― 13 485 руб. The 414D reduces errors, saves time and money. The most advanced laser technology for distance measurement. Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in). Quick calculation of area (square feet/meters) and volume. Pythagoras function indirectly measures height via two other measurements. Stores up to five measurement results. Battery life of 3000 measurements with automatic shut-off feature. Fluke 62 MAX+. Small in size. Big on toughness. Dust and water-resistant: IP54 rated. Rugged: 3-meter (9.8-foot) drop tested. Ergonomically designed: Completely redesigned for a more natural hand fit. Distance to spot: 12:1. Dual lasers: Identifies area to be measured. Large, backlit display: Makes data easier to read, even in dark areas. Fluke 414D Laser Distance Meter Distance Measurement Typical Measuring Tolerance[1] ± 2.0 mm [3] Maximum Measuring Tolerance[2] ± 3.0 mm [3] Range at Leica target plate GZM26 50 m / 165 ft Typical Range[1] 40 m / 130 ft Range at unfavorable condition[4] 35 m / 115 ft Smallest unit displayed 1 mm / 1/16 in ∅ laser point at distances 6 /30 / 60 mm (10 / 50 / 100 m) Tilt measurement Measuring tolerance to laser beam[5] No Measuring tolerance to housing[5] No Range No General Laser class 2 Laser type 635 nm, Protection class IP40 Automatic laser off After 90 seconds Automatic power off after 180 seconds Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements Size (H X W X L) 116mm Length 53mm Width 33mm Depth Weight (with batteries) 113 g Temperature range: Storage Operation -25 °C to +70°C (-13 °F to +158 °F) 0 °C to +40 °C (32 °F to +104 °F) Calibration cycle Not applicable Maximum altitude 3000 m

FL62MAX+/323/1AC ― 13 485 руб.




The 414D reduces errors, saves time and money.
  • The most advanced laser technology for distance measurement.
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).
  • Quick calculation of area (square feet/meters) and volume.
  • Pythagoras function indirectly measures height via two other measurements.
  • Stores up to five measurement results.
  • Battery life of 3000 measurements with automatic shut-off feature.

Fluke 62 MAX+. Small in size. Big on toughness.
  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.




Fluke 414D Laser Distance Meter


Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft
Typical Range[1] 40 m / 130 ft
Range at unfavorable condition[4] 35 m / 115 ft
Smallest unit displayed 1 mm / 1/16 in
∅ laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No
Measuring tolerance to housing[5] No
Range No
General
Laser class 2
Laser type 635 nm,
Protection class IP40
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurements
Size (H X W X L) 116mm Length
53mm Width
33mm Depth
Weight (with batteries) 113 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F)

0 °C to +40 °C
(32 °F to +104 °F)
Calibration cycle Not applicable
Maximum altitude 3000 m
Maximum relative humidity 85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.

Fluke 62 MAX+ Infrared Thermometer


Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

FL62MAX+/323/1AC ― 13 485 руб.

The 414D reduces errors, saves time and money.
  • The most advanced laser technology for distance measurement.
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in).
  • Quick calculation of area (square feet/meters) and volume.
  • Pythagoras function indirectly measures height via two other measurements.
  • Stores up to five measurement results.
  • Battery life of 3000 measurements with automatic shut-off feature.

Fluke 62 MAX+. Small in size. Big on toughness.
  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

Fluke 414D Laser Distance Meter

Distance Measurement
Typical Measuring Tolerance[1] ± 2.0 mm [3]
Maximum Measuring Tolerance[2] ± 3.0 mm [3]
Range at Leica target plate GZM26 50 m / 165 ft
Typical Range[1] 40 m / 130 ft
Range at unfavorable condition[4] 35 m / 115 ft
Smallest unit displayed 1 mm / 1/16 in
∅ laser point at distances 6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5] No
Measuring tolerance to housing[5] No
Range No
General
Laser class 2
Laser type 635 nm,
Protection class IP40
Automatic laser off After 90 seconds
Automatic power off after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000
measurements
Size (H X W X L) 116mm Length
53mm Width
33mm Depth
Weight (with batteries) 113 g
Temperature range: Storage Operation -25 °C to +70°C
(-13 °F to +158 °F)

0 °C to +40 °C
(32 °F to +104 °F)
Calibration cycle Not applicable
Maximum altitude 3000 m
Maximum relative humidity 85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.

Fluke 62 MAX+ Infrared Thermometer

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
2009-2024 © All Rights Reserved
SHOPPING CART
×
ORDERING
×
Surname, First name (Patronymic): *
Full name not specified
Organization: *
Organization not specified
Email: *
Email is incorrect
Phone: *
Phone not specified
Address: *
Address not specified
Comment: (up to 512 characters)
* - required fields
Seller:
Shipping:
Payment:
Order items - , for the amount: 0
Check the final cost and conditions with the seller
By clicking the «SEND ORDER» button, I consent to the processing of personal data
Back to cart
Send order